Transmittal Report: Created by AutoCAD eTransmit Monday, March 26, 2007, 1:25 PM. Drawing Sheet Set: This is a transmittal based on drawing sheets from the sheet set: Rockwall Waterfront Package 2. Sheets: C1 PAVING & HORIZONTAL CONTOL PLAN C1a HORIZONTAL CONTROL PLAN C1b HORIZONTAL CONTROL PLAN C2 GRADING PLAN C3 DRAINAGE AREA MAP C4 WATER & WASTEWATER PLAN C5 SLEEVING PLAN C5a SLEEVING PLAN C6 EROSION CONTROL PLAN DR1 DRAINAGE PLAN DR2 DRAINAGE PLAN DR3 DRAINAGE PLAN DR4 DRAINAGE PLAN DR5 DIMENSION CONTOL PLAN DT1 DETAILS-RWP DT2 DETAILS Files: Root Drawings: C1-PAVE1-RWP.dwg C1a-PAVE1-RWP.dwg C1b-PAVE1-RWP.dwg C2-GRADE-RWP.dwg C3-DRAIN-RWP.dwg C4-WS-RWP.dwg C5-SLV-RWP.dwg C5a-SLV-RWP.dwg C6-EROS-RWP.dwg DRAINAGE-RWP.dwg DRN-CONTROL-RWP.dwg DT1-DETAILS-RWP.dwg DT2-DETAILS-RWP.dwg Sheet Set Data File: Rockwall Waterfront Package 2.dst AutoCAD Drawing (External) References: P-BASE-RWP.dwg EX-STRM-HRLD.dwg EX-WS-RWP.dwg EX-GRADE-HRLD.dwg TOPO-RWP.DWG EX-BASE-PRK-RWP.dwg P-COORDS-RWP.dwg 991_xhard_public&private 071706.dwg 991_O'Brien Building H&J.dwg 991_O'Brien Site_1.dwg 991_O'Brien Site_cinemark.dwg 991_xrestroom.dwg 991_O'Brien Site_2.dwg P-BUOYS.dwg T-BLOCK-RWP.dwg 991_O'Brien Building H&J.dwg P-COORDS PKG2.dwg P-GRADE-RWP.dwg 991_xbase.dwg 991_xcivil_utilities_harold.dwg 991_xcivil_site harold.dwg 991_xcivil_topo_harold.dwg 991 xvistriangle.dwg 991 xhotel.dwg OUT-BLDG-RWP.dwg pkg1-GRADE-EX4PKG2.dwg 991_xmdim_public.dwg pkg1-GRADE.dwg P-DRAIN-BDD.dwg P-WS-RWP.dwg P-STM-RWP.dwg T-BLOCK-TBG-RWP.dwg AutoCAD Font Map References: acad.fmp AutoCAD Color-dependent Plot Style Table File References: Bdd-full.ctb Tbg_Dal.ctb AutoCAD Plotter Configuration File References: 1050C 24x36 Bond.pc3 1050C-2 24x36 Bond.pc3 Microsoft Office Document Imaging File References: P-CONT-SCAN.tif The following files were excluded from the transmittal: simplex.shx txt.shx OPTA.SHX italicc.shx GREEKS.shx ARCHSTYL.shx OPTA-OUT.SHX architxt.shx romans.shx ROB.shx ltypeshp.shx ARIAL.TTF BOLD.shx complex1.shx ROMANT.shx SSFLOW ARW.shx SSFLOWTXT.shx hand.shx ITALIC.shx tbg.shx logo.shx HELV.SHX The following files could not be located: HEL-SO.(shx,ttf) archd.(shx,ttf) 121703 SD Presentation.tif 23224Map.gif bwwlogo.jpg P2.1A.tif P2.1B.tif despc.(shx,ttf) 23224Map.gif bwwlogo.jpg TEXT.(shx,ttf) x-timr1d.(shx,ttf) univ.(shx,ttf) 23224Map.gif bwwlogo.jpg 991 xmatch.dwg 991_xhard_public&private.dwg BDD258.tif archtext.(shx,ttf) OceTDS600 30x42.pc3 The following files were not added because one or more files had the same path in the set already: M:\Data\Civil\2003\C03360 - ROCKWALL WATERFRONT PARK\FILE FROM\TBG\06.09.18\XREFS\991_O'Brien Building H&J.dwg (and M:\Data\Civil\2003\C03360 - ROCKWALL WATERFRONT PARK\ARCHITECTS\01-24-05\Rockwall Private Phase 1 Grading & Drainage\Xref bases\991_O'Brien Building H&J.dwg written to 991_O'Brien Building H&J.dwg). Notes for distribution: .DWG external reference files: External reference (xref) paths were removed, so all xref paths must be placed on the AutoCAD search path, a project search path or in the same directory as the root drawing. eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted Raster image files: Image paths were removed, so all image files must be placed on the AutoCAD search path, a project search path or in the same directory as the root drawing. .PC3 printer configuration files: Please copy these files to the AutoCAD Printer Configuration Search Path directory. .CTB/.STB plot style tables: Please copy these files to the AutoCAD Plot Style Table Search Path directory. The AutoCAD variable FONTALT was set to: C:\Documents and Settings\BDD\Application Data\Autodesk\AutoCAD 2005\R16.1\enu\support\simplex.shx Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font.